Fire and Explosion Risks in Lithium-Ion Battery Energy Storage Stations: Analysis and Prevention Strategies
With the widespread application of lithium-ion batteries in electrochemical energy storage stations, incidents of fires and explosions have become increasingly frequent. To investigate the underlying causes of these accidents in greater depth, a study analyzed 90 fire and explosion events involving lithium-ion battery energy storage stations that occurred worldwide between November 2017 and September 2024.

The analysis focused on four key aspects: battery type, country of occurrence, operational status of the station, and causal factors. The results indicate that ternary lithium batteries are significantly more prone to triggering fire and explosion accidents, with an occurrence rate 2.5 times higher than that of lithium iron phosphate batteries.
These findings underscore a clear message for the energy storage industry: as lithium-ion batteries continue to be widely deployed, prioritizing safety-focused design and material selection becomes essential.
In this context, solid-state batteries offer a promising path forward. Their inherently higher thermal stability and reduced likelihood of leakage or combustion make them particularly suitable for large-scale energy storage applications.
Choosing inherently safer battery technologies is the cornerstone of ensuring the safety of energy storage power stations throughout their entire lifecycle. This is precisely the starting point for all product designs and technological innovations at Super Power.
Statistical Results and Cause Analysis of Accidents
Statistical analysis of the incidents shows that fires and explosions sometimes occur sequentially. Therefore, this study categorizes the consequences into three types: fire incidents, explosion incidents, and fire-explosion incidents, as shown in Figure 1.

Figure 1 Battery Type Distribution in Accidents
Among 85 energy storage station incidents with known battery types, 61 were caused by ternary lithium batteries, accounting for approximately 71.8%.
Ternary lithium batteries exhibit lower thermal stability, making them more susceptible to thermal runaway. They also present a higher fire risk, with thermal runaway propagating more rapidly, and release greater quantities of flammable gases during such events.
Collectively, these factors indicate that ternary lithium batteries pose significantly higher risks than lithium iron phosphate batteries in terms of thermal stability, fire hazards, and explosion potential.

Unlike the high-risk liquid-electrolyte ternary batteries discussed in the report, Super Power’s core products are built around solid-state technology. By using a solid polymer electrolyte, the company fundamentally removes the flammability hazards of conventional liquid systems. As a result, the batteries are intrinsically resistant to fire.

Research shows that the thermal stability of the cathode material plays a decisive role in overall safety. In Super Power’s design, the cathode materials and the solid-state electrolyte work hand in hand, forming a much wider thermal safety window. This synergy greatly raises the threshold for thermal runaway and enhances the system’s resilience under extreme conditions.
● Country Statistics and Cause Analysis

Figure 2 Analysis of Incident Distribution by Country
Statistical analysis shows that fire and explosion incidents in electrochemical energy storage stations have been reported in South Korea, the United States, China, Australia, France, Germany, Belgium, Sweden, the United Kingdom, and Singapore.
Analysis of the battery types used in these incidents shows that over half of the energy storage station accidents in the United States involved ternary lithium batteries. By contrast, the majority of stations in China and EU countries were equipped with lithium iron phosphate batteries, reflecting a regional difference in safety preference and technological adoption.
Among these countries, South Korea recorded the most accidents, 34 in total, representing 37.8% of all cases. Investigation reports point to several recurring causes. Battery defects are one of the primary factors, along with inadequate motor protection systems, poor operating environments, installation negligence, and insufficient management of energy storage facilities.
Another key factor lies in the safety performance of the batteries themselves.
In South Korea, ternary lithium batteries are widely used, largely because they dominate the product portfolios of major domestic battery manufacturers. However, these batteries have relatively lower thermal stability, and their management systems are not always reliable.
Deficiencies in battery management or early warning systems may prevent operators from detecting anomalies in time, allowing potential hazards to escalate unchecked.
● Operating State Statistics and Cause Analysis
Energy storage stations typically go through four key stages: construction, commissioning, operation, and maintenance. Each stage carries its own risks. Deficiencies in system integration, construction quality, maintenance procedures, or safety management can all create hidden hazards that should not be overlooked.

Figure 3 Status statistics of EESSs in accidents
Accident reports reveal a clear pattern. In South Korea, most electrochemical energy storage station incidents occurred during charging or in the idle period immediately after charging. This suggests that improper charging control and thermal management may play a significant role.
As shown in the data, the majority of accidents, 72 in total, represent 80.0% of all recorded cases and occurred during normal operation. This high proportion indicates that operational safety remains the most critical challenge in current energy storage systems.
The following factors may contribute to accidents during the operation of electrochemical energy storage stations:
1. Cumulative effects of long-term operation;
2. Impact of high-temperature environments;
3. System load fluctuations;
4. Insufficient reliability of early warning systems;
5. High state of charge (SOC) leading to overcharging.
Super Power’s energy storage system is built around a comprehensive active defense architecture.
● The three-layer BMS design allows independent, real-time monitoring of every single cell. In practice, this means there are truly no blind spots in safety supervision, offering earlier and more precise detection of faults such as internal short circuits or sudden voltage shifts.

● The system’s liquid thermal management is equally critical. “Cooling system failure” is often listed as the highest risk factor, and Super Power tackles it head-on. A finely tuned liquid-based cooling network keeps the batteries within their optimal temperature range, ensuring steady heat dissipation even in harsh environments. This prevents thermal buildup and maintains overall system stability.

● Overcharging is another hidden danger. Through the coordinated control of the BMS and PCS (Power Conversion System), the battery’s state of charge (SOC) is tightly managed. This design stops overcharging at its source, securing the system against one of the most common triggers of battery failure.

Super Power’s CTC (Cell-to-Container) integration technology not only boosts energy density but also introduces an unprecedented level of safety redundancy.
● Modular design and physical isolation. The CTC approach achieves a higher degree of cell integration while incorporating innovative thermal insulation materials. Within each module, an effective heat barrier is formed. Even if a single cell experiences a severe failure, the system can effectively block heat transfer to adjacent cells, physically cutting off the chain of thermal propagation.
● Dual fire suppression systems. Each Super Power energy storage container is equipped with both gas-based and water-immersion fire suppression systems. The gas system acts swiftly to contain early-stage fires, while the water-immersion system serves as the ultimate safeguard for extreme scenarios. Together, they ensure that any residual risk is fully extinguished and safety is maintained under all conditions.
● Analysis of Causes and Contributing Factors in Accidents
Safety concerns in electrochemical energy storage stations are inherently systemic, with accidents typically arising from the interplay of multiple contributing factors.

Figure 4 Statistical map of the causes of accidents in electrochemical energy stations
Equipment-related factors mainly originate from the batteries themselves, as well as from motor protection and cooling systems, including issues with insulation. Battery-specific problems often include manufacturing defects or natural aging over time. Environmental factors can also play a role. For instance, water intrusion or nearby boiler explosions may trigger lithium-ion battery fires.

Figure 5 Factors inducing safety accidents in lithium-ion battery energy storage systems and their interactions
Human factors, however, stand out as the leading cause of accidents in electrochemical energy storage stations. Of the 90 incidents analyzed, 38 were directly or indirectly linked to human error, representing 43.3% of all cases. This highlights that, despite technical and environmental safeguards, operator actions and management practices remain critical to overall system safety.
1. Human operational errors: Staff at electrochemical energy storage stations may lack adequate training, leading to mistakes such as improper operations or neglect of safety procedures.
2. Incomplete safety management systems: Although countries are continuously improving regulations for all stages of energy storage station operation, the rapid development of storage technologies often outpaces the establishment of effective safety management systems and regulatory oversight. This can result in employees overlooking safety concerns.
3. Delayed emergency response: In the event of an emergency, insufficient response skills or lack of timely action by operators can exacerbate the severity of an incident.
4. Insufficient safety awareness: A low level of safety consciousness among operators and management personnel may lead to the neglect of potential risks, increasing the likelihood of accidents.
Based on the statistical analysis of electrochemical energy storage station accidents, the probability and severity of 90 incidents were assessed according to 15 identified risk factors. Both quantitative and qualitative analyses were conducted to evaluate accident probability and severity, with the Delphi method used to determine severity levels.

Figure 6 Risk levels for risky factors of EESSs
Among the 15 risk factors, five were identified as high-risk: failure of the energy storage system’s cooling system, battery overcharging, insufficient fire protection facilities, abnormalities in BMS/PCS/EMS, and extreme environmental temperatures.
● Prevention measures
To address the identified high-risk factors, the overall safety of electrochemical energy storage stations should be enhanced in five key areas:
strengthening the reliability of cooling systems, optimizing battery system measures to prevent overcharging, improving early warning and safety monitoring technologies, advancing fire protection technologies, and optimizing fire-fighting strategies and tactics.
In addition, to reinforce the systemic safety of EESSs, efforts should focus on battery cell design and manufacturing. Safety management systems should be perfected, and mandatory standards should be implemented to prevent damaged batteries from entering energy storage stations. Research on ultra-early warning technologies should be intensified to enable accident prediction several weeks in advance. Specialized fire-extinguishing agents that are efficient, cooling, explosion-proof, and insulating should be developed, alongside cluster-level battery fire tests.
Avoiding high-risk battery technologies and shifting toward inherently safe, system-reliable solutions is the only sustainable path for the energy storage industry. Super Power’s product philosophy aligns perfectly with this vision and delivers a fully validated safety solution, covering every layer from material design to system integration, from intelligent early warning to ultimate protection.

Residential Energy Storage
Industrial and Commercial Energy Storage
Container-Based Energy Storage
Mobile Energy Storage Charging Stations
Battery-driven Type Energy Storage System